In data centers, server rooms, factories, hospitals and facilities with critical electrical loads, power continuity depends on a properly selected and engineered Uninterruptible Power Supply (UPS) infrastructure. Power outages, voltage fluctuations and utility-related power quality issues can affect the operation of critical systems.
Pegon Proje manages the site survey, load analysis, capacity and backup runtime determination, product selection, engineering design, installation, electrical integration, testing and commissioning processes of UPS systems from end to end. UPS capacity is determined by evaluating existing loads, critical systems, required battery backup runtime, redundancy requirements and future capacity increases.
• Do you need your critical systems to continue operating during power outages?
• Is your existing UPS capacity insufficient for increasing equipment and system loads?
• Are you unsure how many minutes of backup runtime your UPS system can provide?
• Are you uncertain about your battery capacity and the condition of your existing batteries?
• Do you need a redundant UPS architecture for your critical systems?
• Are you planning to upgrade your existing UPS system or increase its capacity?
Pegon Proje evaluates not only UPS power capacity, but also critical loads, backup runtime, battery capacity, electrical distribution infrastructure and redundancy requirements together to design a UPS architecture suitable for the project.
Online UPS systems are designed and implemented according to project requirements for data centers, server rooms, healthcare facilities and industrial applications with critical electrical loads.
For applications with lower power requirements and different protection needs, Line-Interactive or Offline UPS options can be evaluated according to the characteristics of the connected loads.
Existing and planned electrical loads are analyzed to determine the appropriate UPS capacity. Future capacity increases can also be considered during the engineering design process.
Battery capacity and battery banks are sized according to the required operating runtime. Load level, UPS characteristics and target backup runtime are evaluated together during system design.
For projects where power continuity is critical, parallel, modular or redundant UPS architectures can be evaluated according to project requirements.
For supported UPS systems, management infrastructures can be implemented for centralized or remote monitoring of operating status, load level, battery condition, alarms and other system data.
Critical loads, existing electrical infrastructure, power requirements and system operating conditions are analyzed.
UPS capacity, battery capacity, target backup runtime and future growth requirements are evaluated.
The appropriate UPS technology, capacity, battery configuration, electrical connections and required redundancy architecture are determined according to project requirements.
The UPS system, battery banks and electrical connections within the project scope are installed and integrated into the existing power infrastructure.
System operating conditions, load status, battery infrastructure, alarm functions and other components within the project scope are checked before the UPS system is commissioned.
We determine UPS capacity not only according to the current total power demand, but by evaluating critical loads, backup runtime, usage scenarios and future capacity requirements together.
We evaluate the UPS system together with electrical distribution, battery infrastructure and critical loads to create an integrated power infrastructure.
Depending on the facility's continuity requirements, we evaluate modular, parallel and redundant UPS architectures within the project scope.
We manage site survey, load analysis, engineering design, product selection, installation, electrical integration, testing and commissioning processes within a single project scope.
UPS systems are designed according to load capacity, backup runtime and redundancy requirements to support power continuity for server, network and storage infrastructures.
UPS infrastructures are designed for automation, control, IT and other critical electrical loads in manufacturing and industrial facilities across Türkiye.
Particularly in Antalya, UPS solutions are implemented according to project requirements for server rooms, network infrastructure, security systems and other critical electrical loads in hotels and tourism facilities.
UPS systems are designed according to load characteristics and usage scenarios for healthcare facilities, offices, campuses and other corporate buildings where uninterrupted power is required.
If you are planning a new UPS system, increasing the capacity of your existing system or reassessing your battery capacity and backup runtime, let's evaluate the technical requirements of your critical power infrastructure together.
New Project • Load Analysis • Technical Site Survey • Engineering Design • System Upgrade • Installation • Quotation
Phone: +90 533 920 99 14
Email: pegon@pegonproje.com
Request a Free Preliminary Assessment and Consultation
UPS capacity is determined by evaluating the total power requirements of the equipment to be supplied, load characteristics, simultaneous operation, future capacity increases and system operating conditions.
Backup runtime is not fixed. The load connected to the UPS, battery capacity, battery condition and overall system design directly affect operating runtime. The appropriate battery capacity is designed according to the required backup runtime.
In Online UPS systems, the load is continuously supplied through the UPS power conversion infrastructure, making this technology suitable for critical applications with demanding power quality requirements. Line-Interactive UPS systems operate according to a different principle and can be considered for applications with lower levels of criticality. The appropriate UPS type should be selected according to the requirements of the load and the facility.
Yes. Depending on continuity requirements, N+1, parallel or other project-specific redundancy architectures can be designed for data centers and other critical facilities.
This depends on the model and architecture of the existing UPS, its support for parallel operation or modular expansion, and the existing electrical infrastructure. Following a technical assessment, expansion of the existing system or transition to a new UPS infrastructure can be evaluated.
Battery performance is affected by age, operating conditions, temperature, charge-discharge cycles and the operating environment. Battery tests and measurement data available from the UPS system can be evaluated to assess the condition of the existing battery bank.